Stay informed with this twice-weekly e-newsletter sent right to your inbox.
Provided for your information are the “Public Works Standard Details” and the “Water Utilities Standard Details”. These standard details should be utilized on projects involving public improvements. Any modification or deviation from these details will require a written request and authorization from the respective managing department.
Detail sheets are provided in AutoCAD (DWG) and Adobe's Portable Document Format (PDF). You will need the appropriate software application to view these files. Adobe Acrobat Reader can be obtained free of charge through Adobe's web site for viewing the PDF files.
For the Texas Department of Transportation (TxDOT) details, please visit TxDOT's website.
Integral Curb and Gutter
Median Nose Pavers
Separate Curb and Gutter
Valley Gutter
Epoxy Tie Bar - Butt Joint (Existing Pavement to Proposed)
Longitudinal Contraction Joint
Pavement Header
Pavement Reinforcing
Sawed Contraction Joint
Transverse Expansion Joint
5 Foot Sidewalk
5 Foot Sidewalk With Wall
6 Foot Sidewalk
6 Foot Sidewalk With Wall
Sidewalk With Low Wall
Sidewalk Connection to Curb Inlet
Sidewalk Connection to Recessed Inlet
Sidewalk Expansion Joint
Wall Formliner
Permanent Backfill and Repair
Temporary Pavement Repair
Typical Drive Approach Connecting To Asphalt Street With Curb and Gutter
Typical Drive Approach Connecting To Existing Rural Type Asphalt Streets
Typical Drive Approach On A Concrete Street
28′ Concrete Pavement Section
28′ HMAC Rural Pavement Section
28′ HMAC Pavement Section
38′ Concrete Pavement Section
38′ HMAC Pavement Section
45′ Concrete Pavement Section
56′ Concrete Pavement Section
90′ Divided Roadway
120′ Divided Roadway
Reclamation Process - Collector
Reclamation Process - Residential
Continuous Left Turn Lane Channelization
Gore Markings
Left Turn Channelization
Pavement Word and Symbols
Raised Pavement Marker Configurations
Standard Crosswalk and Stop Bar Markings
Transition From Two Lane Undivided to Four Lane Divided
Trapped Turns
Area Inlet Protection
Concrete Washout
Construction Access
Curb Inlet Protection
Filter Bag for Dewatering
Filter Fabric Curb Inlet Protection
Rock Check Dam
Silt Fence
Temporary Curb Protection
Curb Drain
Flume with Sidewalk Crossing
Gabion Mattress to Concrete
Overflow Flume
Subdrains
Pipe Collars
RCP Storm Pipe Embedment
Storm Drain Connection to Existing Drainage Structure
Storm Drain Connection to Existing
Drop Inlet
Recessed Inlet
Curb Inlet
Storm Drain Junction Box
Non-Corrosive Steps
Storm Drain Manhole Cover and Frame
Anchor Bolt
Bolt Cover
Foundation
Specification For Fusing Street Light Taps
Standard Front Line Construction Easement Layout to Transformer
Underground Conduit Crossings
Underground to Overhead Electrical Connections
Ground Boxes
LED Internally Lighted Street Name (ILSN) Sign
LED Internally Lighted Street Name (ILSN) Sign Panel Graphic(JPG, 23KB)
Overhead Street Name Sign Design
Sign Installation Pole and Fabrication
Traffic Signal Structures(PDF, 586KB)
Bollard
Cover Sheet
Dead End Barricade
Detailed Outdoor Sign Graphic(JPG, 8MB)
Project Sign Detail
Project Sign Detail With Tarrant County
Project Sign Detail - Community Development Block Grant (CDBG)
Project Sign Detail - Street Maintenance
Title Block
Gate Valve
Fire Hydrant
Construction Meter - Standard Fire Hydrant Meter Installation
Water Line Markers
Horizontal Thrust Block
Blow-Off Using Fire Hydrant
2″-8″ Combination Air Valve
1″ Water Service (1″ and 3/4″ outlets)
2″ Water Service Detail (2″ and 1-1/2″ outlets)
Meter Vault
Class C Water Embedment
BF-A. Double Check Detector Assembly (6″-10″)- Buried
BF-B. Double Check Detector Assembly (2-1/2″-12″) - Outdoor
BF-C. Double Check Detector Assembly (2-1/2″-12″) - Indoor
BF-D. Premise Isolation RPZ BPA 3/4” to 2″ - Indoor
BF-E. Premise Isolation RPZ BPA 2 1/2″ to 12″ - Outdoor
BF-F. Premise Isolation RPZ BPA 2 1/2″ to 12″ - Outdoor Small
BF-G. Irrigation 3/4” to 2″ BP
BF-G. Premise Isolation 3/4” to 2″ BPA
BF-H. Above Ground BPA Site Placement Property Line
BF-I. Above Ground BPA Site Placement Building Line
BF-J. Fire Line BPA Site Placement Property Line
BF-K. Fire Line DCDA Detail 2.5 to 12 inch Vertical Indoor
BF-L Double Check Assembly 3 to 10 inch Buried
BF-M. Double Check Assembly Buried
Cast in Place Sanitary Sewer Manhole
Pre Cast Concrete Sanitary Sewer Manhole
Outside Drop Manhole
Manhole Abandonment
Standard Manhole Frame and Cover
Water Tight Manhole Frame and Cover
Sanitary Sewer Cleanout
Sanitary Sewer Service
Deep Sanitary Sewer Service
Class B Sewer Embedment
Concrete Encasement
Casing Detail
Project Sign